Starting A Manual Regeneration On A Meter Water Softener(C30 & Above)

 

Here’s how to perform a manual regeneration on Water2buy meter water softeners.

This method will only work for water softeners that have C30 or above on the back of their control valve as seen in the picture below, if you have a pre C30 model please follow this link to the appropriate video.

Water softener labels

 

 

 

 

 

 

 

 

 

 

 

A manual regeneration is recommended in the following scenarios.
You are experiencing hard water after your installation.
Your unit is not using salt.
And simply just to check if your unit is working correctly.

When starting a manual regeneration
Make sure the backwash knob is at the ‘SERV’ position.
Turn the manual backwash knob clockwise to the first position marked ‘BA.WA.’.
Do not run a manual backwash immediately before, after or during an automatic backwash. The cycle is complete when the backwash knob returns to the ‘SERV’ position.

It’s as simple as that!
Congratulations you have just started a manual regeneration cycle.
Depending on your settings it could take from 30-45 minutes to complete this cycle.
The Regeneration Cycle is complete when the dial returns to the SERV position.